Oil-immersed transformer

The main difference between oil-immersed transformers and dry-type transformers is the presence or absence of "oil." Because oil is a liquid and has fluidity, oil-immersed transformers *must* have an outer shell. The shell contains aviation hydraulic oil, in which the transformer's electromagnetic coils are immersed. The electromagnetic coils are not visible from the outside. Dry-type transformers, on the other hand, do not use oil or a shell, and the electromagnetic coils are directly visible. One characteristic is that oil-immersed transformers have an oil conservator that stores aviation hydraulic oil, but now there are also new three-phase oil-immersed transformers that are manufactured without an oil conservator.
The main difference between oil-immersed transformers and dry-type transformers is the presence or absence of "oil." Because oil is a liquid and has fluidity, oil-immersed transformers *must* have an outer shell. The shell contains aviation hydraulic oil, in which the transformer's electromagnetic coils are immersed. The electromagnetic coils are not visible from the outside. Dry-type transformers, on the other hand, do not use oil or a shell, and the electromagnetic coils are directly visible. One characteristic is that oil-immersed transformers have an oil conservator that stores aviation hydraulic oil, but now there are also new three-phase oil-immersed transformers that are manufactured without an oil conservator.

Key words:

Oil-immersed power transformers, dry-type transformers, combined transformers, prefabricated substations

Service Hotline:

Product Description

  The fully sealed power transformer eliminates the oil reservoir, using the corrugated oil tank body's fins as heat dissipation and cooling components. Simultaneously, it expands with the increase or decrease of transformer oil, isolating the transformer interior from the atmosphere, preventing oil degradation, moisture damage to insulation, and aging, thus enhancing operational reliability. The core uses high-quality cold-rolled silicon steel sheets, effectively improving the magnetic flux density within the core, reducing noise, and lowering losses. The coils are wound with high-strength enamelled wire (or paper-covered wire), using a cylindrical (or pancake) structure. The ampere-turns are evenly distributed, the insulation structure is reasonable, and it has strong short-circuit resistance. All fasteners used in the oil tank are fitted with locknuts to ensure that they do not loosen during long-distance transportation or operation. After phosphating treatment, the oil tank surface is coated with a three-proof paint (moisture-proof, mildew-proof, and salt-spray-proof), making it widely applicable in harsh environments such as metallurgy, mining, and petrochemicals.

 

Technical Parameter Table of Sll-M Series 10kV Unregulated Voltage Distribution Transformer

 

 Oil-immersed transformer

 

  The national standard "Energy Efficiency Limit Values and Energy Saving Evaluation Values for Three-Phase Distribution Transformers" defines the S13 type performance parameters as the secondary energy efficiency standard. It has been approved by the State Grid Corporation's "First Batch of Key New Technologies to be Promoted". In 2011, newly added distribution transformers should use energy-saving transformers, promoting the application of S13 and above energy-saving transformers (no less than 25%). From 2012 onwards, all newly added distribution transformers will use S13 and above energy-saving transformers. By the end of the Twelfth Five-Year Plan period, the State Grid system's urban distribution network will have completely replaced S9 and below high-loss transformers.
 
 Oil-immersed transformer
 
Technical Parameters of S13-M Series 10kV Unregulated Voltage Distribution Transformer
 
 Oil-immersed transformer
 
Technical Parameter Table of S11-M-30~2500/10-0.4
 
 Oil-immersed transformer
 
Technical Parameter Table of S12-M-30~2500/10-0.4
 
 Oil-immersed transformer
 
Technical Parameter Table of S13-M-30~2500/10-0.4
 
 Oil-immersed transformer
 
Technical Parameter Table of S14-M-30~2500/10-0.4
 
 Oil-immersed transformer
 

 

 