Specific introduction of the characteristics of dry-type transformer
Release time:
2021-12-07
Dry-type transformer is also necessary to certain cooling, can promote the operation of dry-type transformer more security, dry-type transformer cooling equipment to meet the operation of dry-type transformer, promote dry-type transformer can be more safe and efficient operation. Therefore, dry-type transformers should comply with the following rules on cooling equipment.
Dry-type transformer is also necessary to certain cooling, can promote the operation of dry-type transformer more security, dry-type transformer cooling equipment to meet the operation of dry-type transformer, promote dry-type transformer can be more safe and efficient operation. Therefore, dry-type transformers should comply with the following rules on cooling equipment.

Dry-type transformer workers assemble all cooling equipment according to the requirements of the factory. The cooling system software of the strong oil circulation system must have two separate switching power supplies in operation and can be fully automatic converted. When there is a problem with the switching power supply during work, the full-automatic capital should be invested in the backup power supply and the data signal of the sound box and the light lamp should be transmitted.
For dry-type transformer of strong oil circulation system, when removing the problem cooler, the sound box and light lamp data signals shall be transmitted, and the full-automatic (manual type for water-cooled heat dissipation) capital shall be invested in the reserved cooler; The fan, centrifugal water pump and the attached motor of the oil pump shall have overload, short circuit fault and phase failure maintenance; There should be equipment to monitor the rotation direction of the oil pump motor.
The oil pump of the water cooler shall be installed on the inlet side of the cooler, and the steam pressure in the cooler shall be guaranteed to exceed the pressure of about 0.05MPa under all conditions (other than those required for production and manufacture). Water plug valve shall be provided at the water outlet side of the cooler; check valve shall be installed at the inlet and outlet of submersible pump of each cooler for dry-type transformer cooled by strong oil cooling circulating water.
Key words:
Mobile Website
Sales Hotline
+86 13852525108
Contact: Mr. Zhan
Telephone: +86-514-85811000
E-mail: xxdq@jsxxdq.com
Address: No. 6-6 Kangmin Road, Yizheng City, Yangzhou City, Jiangsu Province