2021-12-14
Most of the applications of dry-type transformers are Class A insulation layer data, with a higher allowable temperature of 105 ℃. Dry-type transformer temperature higher position is the transformer core and electromagnetic coil, the top water temperature second, the next layer of water temperature is lower. Accurately measuring the temperature of the electromagnetic coil is the average temperature, which is about 10 ℃ lower than the hot temperature of the network, thus requiring the top water temperature not to exceed 85 ℃.
Most of the applications of dry-type transformers are Class A insulation layer data, with a higher allowable temperature of 105 ℃. Dry-type transformer temperature higher position is the transformer core and electromagnetic coil, the top water temperature second, the next layer of water temperature is lower. Accurately measuring the temperature of the electromagnetic coil is the average temperature, which is about 10 ℃ lower than the hot temperature of the network, thus requiring the top water temperature not to exceed 85 ℃.

(The temperature at 85°C is essentially raised to 95°C, and the air oxidation rate is doubled.) Correlation between temperature and temperature rise: allowable temperature = allowable temperature rise 40 ℃ (higher temperature of surrounding gas). Therefore, when the surrounding gas temperature exceeds 40 ℃, dry-type transformers are not allowed to overload. At this stage, it is generally felt that when the winding resistance insulation layer of oil-change dry-type transformers is 95 ℃-98 ℃, dry-type transformers have all normal service life of about 20 years.
If the temperature to 105 ℃, the use period is about seven years, the temperature at 125 ℃, the use period is about 2 years. Only the top water temperature and temperature increase does not exceed the control value, can ensure the safety of the dry-type transformer long-term operation. The overload operation accelerates the irreversible aging of dry-type transformers.
Reduce the service life of dry-type transformers. For example, in the transformer oil chromatography of a power supply bureau in the 1990 s, it was found that the total hydrocarbon of 7 110 ~ 225kV dry-type transformers exceeded the standard, which was caused by partial over-temperature. Immediately after the incident, the 7 transformers with partial over-temperature were limited to load operation to prevent partial over-temperature of dry-type transformers from appearing again.