What is the transformer noise control scheme of transformer manufacturers?


Release time:

2022-07-01

The transformer manufacturer's transformer is a device that uses the principle of electromagnetic induction to change the AC voltage. The main components are the primary coil, the secondary coil and the iron core (magnetic core). The main functions are: voltage transformation, current transformation, impedance transformation, isolation, voltage regulator (magnetic saturation transformer), etc.

The transformer manufacturer's transformer is a device that uses the principle of electromagnetic induction to change the AC voltage. The main components are the primary coil, the secondary coil and the iron core (magnetic core). The main functions are: voltage transformation, current transformation, impedance transformation, isolation, voltage regulator (magnetic saturation transformer), etc.

1. transformer manufacturer ground independent distribution room transformer noise control

1. Treatment plan: First, maintain the transformer after the power failure, including replacing the old transformer oil, checking the transformer fasteners, and removing dust. Secondly, strengthen or install the transformer foundation, and select the rubber pad or spring damper according to the vibration condition; strengthen the sound insulation of the weak part of the distribution room. The ordinary window is changed to anechoic ventilation window, and the ordinary iron door or aluminum alloy door is changed to wooden fireproof sound insulation door or metal sound insulation door.

2. Empirical analysis: First of all, at the initial stage of design, the noise problems that may exist in such power distribution rooms should be considered, and the power distribution room should be as far away from the main body of the house as possible. Secondly, the transformer foundation should be strengthened as much as possible to restrain the amplification of transformer vibration or install shock absorbers on the transformer. The weak parts of sound insulation such as doors and windows of the distribution room should not face the main body of the house as much as possible. If unavoidable, the doors and windows of the distribution room shall be designed as soundproof doors and windows.

Noise control of grounding box-type transformer of 2. transformer manufacturer

1. Treatment plan: First, maintain the transformer after the power failure, including replacing the old transformer oil, checking the transformer fasteners, and removing dust. Secondly, strengthen the transformer foundation or install the isolation device, and choose the rubber pad or spring shock absorber according to the vibration degree; because the shell of the box-type substation is relatively thin, the shell is difficult to sound insulation and reinforcement, and the location space is small, so the box-type substation The noise processing method is to set up a sound barrier or shell outside. In general, after the above treatment, the noise of the box-type transformer basically meets the requirements of national standards. If the sound insulation cover needs to consider the heat dissipation of the box-type transformer, the air intake system and the exhaust system are generally required.

2. Empirical analysis: First, at the initial stage of design, the possible noise problems of such box-type substations should be considered, and the box-type substations should be as far away from the residential body as possible; Secondly, the transformer foundation in the box-type transformer should be reinforced to restrain the amplification of transformer vibration, or the transformer should be equipped with shock absorbers; If it is impossible to avoid being far away from the main body of the house, a sound barrier should be installed on the sensitive side of the box-type transformer. If the sound insulation screen cannot isolate noise in the future, it can be considered to install a sound insulation cover in the box-type transformer to suppress noise.

3. transformer manufacturer basement distribution room transformer noise control

1. Treatment plan: First, block the vibration of the transformer, including replacing the low-voltage outgoing bus of the transformer, fastening the fasteners of the transformer, the transformer shell and the transformer body, installing rubber pads or shock absorbers at the bottom of the transformer, and changing the grounding flat iron into grounding braid; Secondly, the power distribution room needs sound insulation. Install sound insulation or sound absorbing materials around the distribution room for sound insulation and absorption.

2. Empirical analysis: first of all, in the early stage of design, the noise problem that may exist in the basement distribution room should be considered, and the distribution room should be as far away from the residential projection as possible. Secondly, the foundation of the transformer in the box should be strengthened as much as possible to restrain the amplification of transformer vibration or install a shock absorber on the transformer.