How is the transformer of the transformer manufacturer cleaned and maintained?


Release time:

2022-07-11

Transformer manufacturers of transformer cleaning and maintenance methods are as follows: 1. Ensure the quality of insulating oil: In the process of storage, transportation or operation and maintenance of transformer insulating oil of transformer manufacturers, if the oil quality is poor or the impurities and moisture are too much, the insulation strength will be reduced. When the insulation strength is reduced to a certain value, the transformer will short-circuit, causing electric sparks, arcs or dangerous temperatures. Therefore, the oil quality of the transformer should be tested regularly during operation, and the unqualified ones should be replaced in time.

Transformer manufacturers of transformer cleaning and maintenance methods are as follows:

1. Ensure the quality of insulating oil:

In the process of storage, transportation or operation and maintenance of transformer insulating oil of transformer manufacturers, if the oil quality is poor or the impurities and moisture are too much, the insulation strength will be reduced. When the insulation strength is reduced to a certain value, the transformer will short-circuit, causing electric sparks, arcs or dangerous temperatures. Therefore, the oil quality of the transformer should be tested regularly during operation, and the unqualified ones should be replaced in time.

2. Prevent transformer overload operation:

Long-term overload operation will cause coil heating, insulation aging, short circuit between boxes, short circuit between phases or short circuit to ground, and oil decomposition.

3, to prevent the transformer core insulation aging damage:

The iron core insulation is aging or the clamping bolt sleeve is damaged, resulting in excessive eddy current of the iron core, resulting in long-term heating of the iron core and insulation aging.

4. Ensure that the conductor is in good contact:

Poor contact of the internal joints of the coils, poor contact of the connection points between the coils, contacts leading to the high and low voltage side bushings, and fulcrums on the tap changer can cause local overheating, insulation damage, short circuits or open circuits. The high-temperature arc generated at this time will decompose the insulating oil and generate a large amount of gas, which will increase the pressure in the transformer. When the pressure exceeds the set value of the gas circuit breaker protection without tripping, an explosion will occur.

5. Prevent insulation damage caused by careless maintenance:

When the transformer manufacturer's transformer is overhauled, pay attention to protect the coil or insulating sleeve. If damage is found, it should be dealt with in time.

6. Short circuit protection shall be reliable:

If the transformer coil or load is short-circuited, the transformer will withstand a considerable short-circuit current. If the protection system fails or the protection setting value is too large, the transformer may be burned. To this end, install a reliable short-circuit protection device.

7. Electric shock protection:

The power supply of power transformers usually comes from overhead lines. Overhead lines are prone to lightning strikes, and transformers will be burned due to insulation breakdown.

8. Maintain good grounding:

For the low-voltage system with protection zero, the neutral point of the low-voltage side of the transformer shall be directly grounded. When the three-phase load is unbalanced, there will be current on the neutral line. When the current is too large and the contact resistance is too large, the grounding point will have high temperature and ignite the surrounding combustibles.

9. Prevent overheating:

During the operation of the transformer manufacturer's transformer, the temperature change shall be monitored. If the transformer coil conductor is a-class insulation, the insulation is mainly paper and cotton yarn. Temperature has a great influence on insulation and service life. When the temperature rises by 8 ℃, the insulation life will be reduced by about 50%. The transformer operates at room temperature (90°C) and has a service life of about 20 years; if the temperature rises to 105°C, the service life is 7 years. 5 If the temperature rises to 120°C, the service life is only two years. Therefore, during the operation of the transformer, to maintain good ventilation and cooling. If necessary, forced ventilation can be used to reduce the temperature rise of the transformer.